FEATURES
- Timer for test function (count 3-5 minutes).
 - Three insulation test voltages(DC V) : 250V, 500V, 1000V.
 - 3½ digital LCD (2000 counts).
 - 68 × 34mm (2.677” × 1.338”) large LCD display.
 - Automatic circuit discharge.
 - Test insulation at rated voltage into a 1mA load.
 - 200mA short circuit testing current for continuity.
 - External voltage warning indication.
 - Fuse protection.
 - Data hold function
 - Auto power off function.
 - BS 16th edition.
 
SPECIFICATIONS
Insulation Resistance
| Test voltage (DC V)  | 
250V / 500V / 1000V | 
|---|---|
| Measuring ranges (Auto ranging)  | 
0-20MΩ / 0-200MΩ / 0-2000MΩ | 
| Accuracy | 0-20MΩ : ±(1.5%rdg+5dgt) 0-200MΩ : ±(2.5%rdg+3dgt) 0-2000MΩ : ±(5%rdg+5dgt)  | 
| Output voltage on open circuit | Rated test Voltage +10% | 
| Output current | 1mA DC | 
| Power consumption | 250mA | 
Continuity
| Measuring range | 0-20Ω / 0-200Ω / 0-2000Ω | 
|---|---|
| Accuracy | ±(1.5%rdg+3dgt) | 
| Resolution | 0.01Ω / 0.1Ω / 1Ω | 
| Buzzer sound below | under 10Ω | 
| Open circuit terminal voltage | 4V DC min. | 
| Short circuit terminal current | 200mA DC min. | 
| Power consumption | 300mA max | 
AC Voltage
| Range | 0-600V AC | 
|---|---|
| Resolution | 1V | 
| Line frequency range | 40-120 Hz | 
| Accuracy | ±(1.5%rdg+3dgt) | 
General
| Display | 3½ digit (2000 counts) | 
|---|---|
| Dimensions | 205(L) × 90(W) × 55(D)mm | 
| Weight (battery included)  | 
Approx. 550g | 
| Power source | 1.5V (AA ) × 6 | 
| Safety standard | EN IEC 61010-1 CAT III 600V EN 61326-1  | 
						

 