FEATURES
- Designed for testing AC current and AC voltage.
- 5 ranges for AC current testing.
- The best resolution of leakage current measurement is 0.1mA.
- Frequency selection : 50/60 Hz and Wide.
- Data hold function.
- Low battery indication.
SPECIFICATIONS
AC Current
Ranges | Accuracy | |
---|---|---|
50/60Hz | WIDE | |
200mA(0~199.9mA) | ±(1.5%rdg+2dgt) | 40/1000Hz : ±(3.0%rdg+2dgt) |
2A (0~1.999A) | ||
20A(0~19.99A) | ||
200A(0~199.9A) | ±(2.0%rdg+2dgt) | 40/1000Hz : ±(3.5%rdg+2dgt) |
0-500A | ±(2.0%rdg+2dgt) | 40/1000Hz : ±(3.5%rdg+2dgt) |
501-1000A | ±5.5%rdg | 40/1000Hz: ±10%rdg |
AC Voltage
Ranges | AC600V / DC600V |
---|---|
Resolution | 1V /1V |
Accuracy | ±(1.5%rdg+3dgt)/ ±(1.0%rdg+2dgt) |
GENERAL
Conductor size | 55mm Max. |
---|---|
Operating principle | Dual slope integration |
Display | 3½ digit (2000 counts) |
Low battery indication | ""sign appears on the display when the battery voltage drops below accurate operating level |
Overload protection | AC 600V / DC 600V |
Data hold Indication | HOLD |
Response time | Approx. 1 second |
Sample rate | Approx. 2 times per second |
Temperature & humidity for guaranteed | ºC to 50ºC at < 80% Max. relative humidity |
Storage temperature & humidity | -10ºC to 60ºC at < 80% Max. relative humidity |
Battery life | Approx. 100 hours on continuous use. (Alkaline) |
Dimensions | 276(L) × 95(W) × 43(D)mm |
Weight (battery included) |
Approx. 540g |
Power source | 9V(6F22) × 1 |
Safety standard | EN 61010-1 CAT III 600V EN 61010-2-32 EN 61326-1 |
Feedback list