FEATURES
- Big-size LCD (112 x 59mm)
- Backlight function.
- Analog scale with Bar-graph for viewing. (100 bars)
- 10000 counts (high resolution).
- DCV Ranges: 99.99mV~999.9V (ST-2001 DCV).
- ACV Ranges: 99.99mV~800.0V (ST-2001 ACV).
- 5 manual ranges controlled by rotary switch.
- Data Hold function
- Low battery indication
- 9V power supply
- Best resolution of 0.01mV (10uV)
- Precision meter for factory maintenance, field servicing and educational purposes.
- With an optical USB to RS-232 data transmission cable. (DCV-R & ACV-R)
- 2 optical LEDs are built-in for data transfer. (DCV-R & ACV-R)
- Well isolated to contact. (DCV-R & ACV-R)
- The software is included (Compact disc). (DCV-R & ACV-R)
SPECIFICATIONS
AC Voltmeter
| Range | Resolution | Accuracy | 
|---|---|---|
| 100.00mV | 10uV | 50/60Hz : ±(0.3%rdg+5dgt) 40~400Hz : ±(0.5%rdg+6dgt) | 
| 1000.0mV | 100uV | |
| 10.000V | 1mV | |
| 100.00V | 10mV | |
| 800.0V | 100mV | 
SPECIFICATIONS
| Operating temperature & humidity | 0°C ~ 40°C, 80% Max. R. H. | 
|---|---|
| Storage temperature & humidity | -10°C ~ 50°C, 80% Max. R. H. | 
| Dimensions (with holster) | 177 (L) x 200 (W) x 105 (D)mm | 
| Weight (battery included) | Approx. 1190g | 
| Power source | 1.5V (AA) x 6 | 
| Safety standard | EN 61010-1 EN 61326-1 | 
 
						


 
 
Feedback list