Product Category

1813 EL

Datasheet print icon-img

FEATURES

  • Microprocessor-controlled.
  • 2 Lines × 16 characters LCD.
  • Very low consumption.
  • Suitable for domestic version.
  • Better than 3% accuracy (current).
  • Menu-driven.
  • Accurate digital readout of disconnection time.
  • Accurate digital readout of disconnection sensitivity.
  • Automatic data hold function.
  • Zero crossing circuitry permit testing at 0° or 180°.
  • Disconnection phase polarity shown on LCD display.
  • Auto off and off override.
  • Polarity trip indicator (positive or negative phase)
  • Wiring polarity indicator.
  • Measure voltage between Line and Earth before testing.
  • 60Hz available.

SPECIFICATIONS

System voltage (50Hz / 60Hz) 550V
380V
240V
Current settings 2-999mA ac
Current selection Knob
Phase start selection
referenced to earth
0° and 180°
Over-temperature protection Yes
Wiring correction indication Yes
Phase polarity trip indicator Yes
Operating voltage (L-E) 110 Vac to 317 Vac
Timer resolution 1ms (Max. Time=19.999s)
Timer accuracy 1ms ±1ms
Current accuracy ±1% ±1mA
Current resolution 1mA
Voltmeter accuracy (50Hz) 50-350 Vac : ±2%±1V
350-450 Vac : ±5%±1V
Voltmeter resolution 1V
Voltameter resolution ±2%±1Vac
Operating temperature -5°C to 40°C
Storage temperature -10°C to 55°C
Dimensions 170(L) × 165(W) × 92(D)mm
Weight
(battery included)
Approx. 1300g
Power source 1.5V (AA) × 8