FEATURES
- 3½ digit, high contrast LCD, with a maximum display of 1999
- Automatic polarity indication, zero adjustment
- Low battery (BAT) indication
- Over range indication: highest digit of (1) or (-1)
- EN 61010-1 CAT III 600V, EN 61326-1
ANALOG DISPLAY
- Large 90º wide and 84mm long mirror scale. (adapted to digital, analogue maximum indication 2400)
- Shock and vibration resistant TAUT BAND movement
- Pointer can be selected to either left-hand zero (normal mode) or center zero (galvo-mode)
- In galvo-mode pointer deflects right to indicate positive polarity and left to indicate negative polarity
- Automatic center zero and ohm zero
- Dimensions: 175(L) × 109(W) × 44(D)mm
SPECIFICATIONS
DC Voltage
Input impedance : 10MΩ
Ranges | Analogue Maximum |
Resolution Digital |
Accuracy | Protections | |
---|---|---|---|---|---|
Digital | Analsogue | ||||
200mV | 240mV | 100μV | ±(1%rdg+1dgt) | ±3%F.S. | DC500V AC350V |
2V | 2.4V | 1mV | |||
20V | 24V | 10mV | DC1200V AC800V |
||
200V | 240V | 10mV | |||
600V | 600V | 1V |
AC Voltage
․Input impedance : 10MΩ
Ranges | Analogue Maximum |
Resolution Digital |
Accuracy | Protesction | |
---|---|---|---|---|---|
Digital | Analogue | ||||
200mV | 240mV | 100μV | ±(1%rdg+5dgt) | ±3%F.S. | DC500V AC350V |
2V | 2.4V | 1mV | |||
20V | 24V | 10mV | DC1200V AC800V |
||
200V | 240V | 10mV | |||
600V | 600V | 1V | ±(1.5%rdg+5dgt |
DC Current
Ranges | Analogue Maximum |
Resolution Digital |
Accuracy | Protection | |
---|---|---|---|---|---|
Digital | Analogue | ||||
200uA | 240uA | 100nA | ±(1%rdg+5dgt) | ±3%F.S. | 800mA |
2mA | 2.4mA | 1μA | |||
20mA | 24mA | 10μA | |||
200mA | 240mA | 100μA | |||
10A | 10A | 10mA | ±(2%rdg+3dgt) | 10A |
AC Current
Ranges | Analogue Maximum |
Resolution Digital |
Accuracy | Protection | |
---|---|---|---|---|---|
Digital | Analogue | ||||
200uA | 240uA | 100nA | ±(1%rdg+5dgt) | ±3%F.S. | 800mA |
2mA | 2.4mA | 1μA | |||
20mA | 24mA | 10μA | |||
200mA | 240mA | 100μA | |||
10A | 10A | 10mA | ±(2%rdg+3dgt) | 10A |
Resistance
Ranges | Analogue Maximum |
Resolution Digital |
Accuracy | Protection | |
---|---|---|---|---|---|
Digital | Analogue | ||||
200Ω | 5kΩ | 100mΩ | ±(1%rdg+5dgt) | ±4%arc -10Ω |
50V DC |
2kΩ | 50kΩ | 1Ω | |||
20kΩ | 500kΩ | 10Ω | ±4%arc | ||
200kΩ | 5MΩ | 100Ω | |||
2000kΩ | 50MΩ | 1kΩ | |||
20MΩ | 500MΩ | 10kΩ | ±(1.5%rdg+5dgt) |
Capacitance
Ranges | Analogue Maximum |
Resolution Digital |
Accuracy | Protection | |
---|---|---|---|---|---|
Digital | Analogue | ||||
2000pF | 2400pF | 1pF | ±(3%rdg+10dgt) | ±5%F.S. | 50mV 400Hz |
20nF | 24nF | 10pF | |||
200nF | 240nF | 100pF | |||
2uF | 2.4nF | 1nF | |||
20uF | 24uF | 10nF |
Instant Continuity
Ranges | Analogue Maximum |
Resolution Digital |
Continuity Indication |
Test Voltage |
---|---|---|---|---|
200Ω | 5kΩ | 100mΩ | Built Buzzer sounds when Resistance is less than 40Ω | 3.2V MAX |
Frequency
Ranges | Analogue Maximum |
Resolution Digital |
Accuracy | Test Voltage | |
---|---|---|---|---|---|
Digital | Analogue | ||||
2000Hz | 2400Hz | 1Hz | ±(2%rdg+3dgt) | ±3%F.S. | 350Vrms |