FEATURES
- Display: 3½ digit liquid crystal display (LCD) with max. reading of 1999.
- Polarity: Automatic, (-) negative polarity indication.
- Zero Adjustment: Automatic.
- Over Range Indication: Highest digit of (1) or (-1) is displayed.
- Low Battery Indication: The (BAT) is displayed when the battery voltage drops below the operating voltage.
- Measurement Rate: 3 measurements per second, nominal.
- Operating Temperature: 0°C to ±50°C, 0-70% RH.
- Storage Temperature: -20°C to +60°C, 0-80% RH, with battery removed.
- Accuracy: Accuracy specifications at 23±5°C, less than 75% RH.
- Power: Single, 006P 9 volt battery
- Dimensions: 128(L)×72(W)×33(D)mm.
- Weight: Approx .200g
SPECIFICATIONS
DC Voltage
․Input impedance : 10MΩ
Ranges | Resolution | Accuracy | Over voltage Protection |
---|---|---|---|
200mV | 100nV | ±(0.5%rdg+1dgt) | DC 500V AC 350V |
2V | 1mV | ||
20V | 10mV | DC 1200V AC 800V |
|
200V | 100mV | ||
1000V | 1V |
AC Voltage
Input impedance : 10MΩ
Ranges | Resolution | Accuracy | Over voltage Protection |
---|---|---|---|
200mV | 100μV | 45 Hz to 400 Hz ±(1.2%rdg+4dgt) |
DC 500V AC 350V |
2V | 1mV | ||
20V | 10mV | DC 1200V AC 800V |
|
200V | 100mV | ||
1000V | 1V |
DC Current
Overload Protection0.8A(250V) fast blow fuse
Ranges | Resolution | Accuracy | Over voltage Protection |
---|---|---|---|
200μA | 100nA | ±(1.0%rdg+1dgt) | 325mV max |
2mA | 1μA | ||
20mA | 10μA | ||
200mA | 100μA | ||
10A | 10mA | ±(2.0%rdg+3dgt) | 700mV max |
AC Current
Overload Protection0.8A(250V) fast blow fuse
Ranges | Resolution | Accuracy 45 Hz to 400 Hz |
Over voltage Protection |
---|---|---|---|
200μA | 100nA | ±(1.2%rdg+1dgt) | 325mV max |
2mA | 1μA | ||
20mA | 10μA | ||
200mA | 100μA | ||
10A | 10mA | ±(2.0%rdg+3dgt) | 700mV max |
Resistance
Ranges | Resolution | Accuracy | Max test current | Max open circuit voltage |
---|---|---|---|---|
200Ω | 0.1Ω | ±(1.0%rdg+3dgt) | 3mA | 3.2V |
2kΩ | 1Ω | ±(0.8%rdg+1dgt) | 250uA 50uA 5uA 500nA |
0.3V |
200kΩ | 10Ω | |||
200kΩ | 100Ω | |||
2MΩ | 1kΩ | |||
20MΩ | 10kΩ | ±(3.0%rdg+1dgt) | 50nA |
Capacitance
Ranges | Resolution | Accuracy | Over voltage Protection |
---|---|---|---|
2000pF | 1pF | ±(3%rdg+10dgt) | 500mV 400Hz |
20nF | 10pF | ||
200nF | 100pF | ||
2uF | 1nF | ||
20uF | 10nF |