FEATURES
- Microprocessor controlled.
-
Four insulation test voltages (DC) :125V, 250V, 500V, 1000V
- The maximum insulation measurement range is 200GΩ @1000V.
- 1mA test current on insulation test at nominal voltage.
- Large LCD (74 × 45mm).
- Auto-ranging.
- Bar-graph indication.
- Backlight function.
- REL(Auto-null) function.
- AC/DC auto detection for 600V.
- Diode testing
- Auto-test stop & smart hold.
- Supplied with high quality test leads.
-
Safety standard :IEC/EN 61010-1 CAT III 600VIEC/EN 61010-2-034EN IEC 61326-1
SPECIFICATIONS
Insulation Resistance(GΩ)
Test voltage (DC V) |
125V / 250V / 500V / 1000V |
---|---|
Measuring ranges | 0-25GΩ / 0-50GΩ / 0-100GΩ / 0-200GΩ |
Output voltage open circuit | Rated test voltage +10% |
Accuracy | ±(3%rdg+5dgt) |
Output short-circuit current | ≥ 1.0mA |
AC/DC Voltage
Measuring ranges | 600V AC/DC auto detection |
---|---|
Accuracy | ± (3%rdg+5dgt) |
Resistance
Measuring ranges | 20.00kΩ / 200.0kΩ / 2000kΩ / 20.00MΩ |
---|---|
Accuracy | ± (3%rdg+3dgt) |
Continuity
Measuring ranges | 20.00Ω / 200.0Ω / 2000Ω |
---|---|
Buzzer | under 10Ω |
Open circuit voltage | 5V±1V |
Short circuit current | >210mA |
Accuracy | ± (3%rdg+5dgt) |
Feedback list