Product Category

8020 ER

Datasheet print icon-img

FEATURES

  • Capable of measuring earth resistance and earth voltage.
  • 2mA measuring current permits the testing of earth resistance without tripping earth leakage current breakers in the circuit under test.
  • Frequency : 820Hz.
  • 0Ω adjustment.
  • Battery operated.
  • Data hold function.
  • Low battery indication.
  • Calibration performed with supplied test leads.
  • Simplified measurement probe is also provided for two-wire measuring method.

SPECIFICATIONS

Measuring ranges Earth resistance
0-20Ω / 0-200Ω / 0-2000Ω
Earth voltage
0-200 Vac (40-500Hz)
Accuracy Earth resistance ±(1.5%rdg+2dgt)
or ±0.1Ω, which is greater
Earth voltage ±(1%rdg+2dgt)
Earth resistance resolution 0-20Ω : 0.01Ω
0-200Ω : 0.1Ω
0-2000Ω : 1Ω
Testing frequency 820 Hz
Measuring system Earth resistance by constant current inverter 820Hz approx 2mA.
Display 3½ digit (2000 counts)
0Ω adjustment
Open circuit indication LED will be unlit
Low battery indication "" symbol appears on the display
Data hold indication "" symbol appears on the display
Over range indication “1”(MSD)
Dimensions 221(L) × 110(W) × 57(D)mm
Weight (battery included) Approx. 600g
Power source 1.5V (AA) x 6
Safety standards IEC/EN 61010-1 CAT IV 200V
EN 61557-1 EN 61557-5
EN 61326-1

Feedback list

Post your feedback
Cart

Login

Login Success