3902 CL

Datasheet print icon-img

FEATURES

  • 2000 - count LCD.
  • Full automatic measurement.
    • Voltage measurement.
    • Current measurement.
    • Resistor measurement.
    • Capacitor measurement
    • Frequency counter.
  • Range change function.
  • Data Hold function freezes the reading.
  • Continuity check.
  • Diode measurement.
  • Low battery indication.
  • Auto Power Off (APO) function.
  • Safety design throughout with no exposed metal parts, shielded banana plugs and recessed input terminals.

SPECIFICATIONS

AC A 200.0/2000A (40~500Hz)
0~1500A ±(1.5%rdg+4dgt)
1500A~2000A ±(2.5%rdg+4dgt)
AC V 200.0mV ±(2.0%rdg+3dgt)
2.000/20.00/200.0/750V
±(1.5%rdg+3dgt) 40~500Hz
DC A 200.0/2000A
0~1500A ±(1.5%rdg+4dgt)
1500A~2000A ±(2.5%rdg+4dgt)
DC V 200.0mV/2.000/20.00/200.0/1000V
±(1.0%rdg+3dgt)
Ω + Continuity 200.0Ω/2.000/20.00/200.0kΩ/2.000MΩ
±(1.5%rdg+3dgt)
20.00MΩ ±(2.0%rdg+4dgt)
Hz 2.000/20.00kHz
±(0.5%rdg+2dgt)
Capacitor 2.000/20.00/200.0nF/2.000/20.00/200.0uF
±(3.0%rdg+5dgt)
2.000mF ±(15%rdg+5dgt)
Bargraph ──
Display 3½ (2000 counts)
Auto-ranges
Data hold
Low battery indication
Auto power-off
Max/Min. Mode ──
Relative mode ──
Conductor size 55mm Max.
Operating temperature & humidity 0ºC ~ 40ºC at < 80% RH
Dimensions 265(L) × 100(W) × 42(D)mm
Weight
(battery included)
Approx. 510g
Power source 9V(6F22) × 1
Safety standard EN 61010-1 CAT III 600V
EN 61010-2-32
EN 61326-1