Product Category

2706 IM

Datasheet print icon-img

FEATURES

  • True measurement of speaker systems actual impedance at 1kHz.
  • Three test ranges (20Ω / 200Ω / 2000Ω) allow testing of home theater and commercial sound systems.
  • Measures transformer impedances.
  • Battery operated.
  • Low battery indication.
  • Data hold function.
  • Timer function for continuous hands free operation.
  • The timer can last about 3-5 minutes when users press.
  • TEST ON/OFF button.

SPECIFICATIONS

Measuring ranges 0-20Ω / 0-200Ω / 0-2000Ω
Test frequency 1kHz
Accuracy 20Ω : ± 2%rdg±2dgt or ± 0.1Ω,
which is greater
200Ω / 2000Ω : ± 2%rdg±2dgt
Low battery indication “ Symbol appears on the display
Data hold indication “ Symbol appears on the display
Display LCD 3½ digit (2000 counts)
Dimensions 205(L) × 90(W) × 55(D)mm
Weight
(battery included)
Approx. 530g
Power source 1.5V (AA) × 6
Safety standard EN 61010-1 CAT III 300V
EN 61326-1