FEATURES
- 4-20mA (1kΩ load, 24V Loop Supply).
- 0.025% Basic Accuracy.
- Simple Operation Interface.
- Auto Ramp and Step Functions.
- 0-20mA, 0-24mA selectable.
- Incremental percentage setting : 0-100%.
- Warning beeper when output is open.
- 0-24V output.
- The minimum load of 20kΩ on voltage mode.
SPECIFICATIONS
DC Current (1kΩ Max Load, 24v Loop Supply)
Beeper warning when output circuit is open and specified output voltage > 24V.
Range |
0-4mA / 4-20mA / 20-24mA |
Resolution |
1uA |
Accuracy |
±0.025%±10uA / ±0.025%±5uA / ±0.025%±5uA |
DC Voltage (Approx. 10MΩ load)
Beeper warning when voltage is short and specified output current is > 24mA.
Range |
0-4V / 4-20V / 20-24V |
Resolution |
1mV |
Accuracy |
±0.05%±10mV / ±0.05%±5mV / ±0.05%±5mV |
General
Power
consumption |
150mA at 24V 1kΩ load |
Operating
temperature |
0º C - 40º C |
Operating
humidity |
≤ 80% R.H. |
Storage
temperature |
-10º C - 50º C |
Storage humidity |
≤ 85% R.H. |
Dimensions |
160(L) × 100(W) × 38(D)mm |
Weight
(battery included) |
Approx. 350g |
Power source |
9V(6LF22) × 1 Alkaline battery |
Safety standard |
EN 61326-1 |
Feedback list