FEATURES
- Microprocessor-controlled.
- Measure down to 1μΩ.
- 6 ranges from 2.000mΩ to 200.0Ω.
- Maximum resolution of 1μΩ.
- Three test currents with over-temperature protection.
- Four terminal measurement.
- Protection against inadvertent connection to over-voltage. (crow bars for current and voltage)
- Clear & large LCD.
- Potential lead resistance and current lead resistance checks.
- "Full-featured” EnerSave™ Inside.
- EnerSave™ Auto-hold.
- EnerSave™ Auto-off.
- Rechargeable battery operated
- Robust & compact.
- Indicators show if reading may be invalid (RP, RC, and temperature).
- "O-Ring” sealed case.
SPECIFICATIONS
Low resistance ranges / resolution | 0-2.000mΩ / 1μΩ 0-20.00mΩ / 10μΩ 0-200.0mΩ / 100μΩ 0-2.000Ω / 1mΩ 0-20.00Ω / 10mΩ 0-200.0Ω / 100mΩ |
---|---|
Accuracy | 0-2.000mΩ : ±(5%rdg+5dgt) 0-20.00mΩ : ±(4%rdg+4dgt) 0-200.0mΩ : ±(4%rdg+4dgt) 0-2.000Ω : ±(3%rdg+4dgt) 0-20.00Ω : ±(2%rdg+4dgt) 0-200.0Ω : ±(2%rdg+4dgt) |
Test current (dc) | 2.000mΩ to 200.0mΩ : 1A±3% 200.0mΩ to 20.0Ω : 100mA±2% 200.0Ω : 10mA±1.5% |
Maximum output voltage (C1~C2) | 10V |
Dimensions | 330(L) × 260(W) × 160(D)mm |
Weight (battery included) |
Approx. 3200g |
Power source | Rechargeable battery |
Safety standard | EN 61010-1 EN 61326-1 |
Feedback list