FEATURES
- Waterproof design, protection class : IP65.
- Excellent shock resistance.
- Rugged nylon moulding.
- Auto on (when voltage detected).
- Excellent drop resistance.
- Good vibration resistance.
- Loud sound alarm indication.
- Built-in proving and self-test circuit.
- High bright color-coded LEDS.
- Works from standard 9V battery.
- Interchangeable contact electrode.
- Use in all whether conditions.
- Compatible with all link sticks.
- Lightweight, robust & compact.
- Models available from 11kV to 132kV.
- Suitable for indoor and outdoor use.
- Self(auto on) or manual arming.
- Easy access to batteries.
- Customized threshold on demand.
- Auto off (if no voltage detected).
-
Dimensions:300(L) × 100(W) × 100(D)mm
-
Weight:Approx. 550g (battery included)
-
Meets EN 61243-1(excludes 220HVD, 221HVD, 225HVD)
SPECIFICATIONS
PART# | 213HVD | 214HVD | 215HVD | 216HVD |
---|---|---|---|---|
System Voltage | 11kV | 33kV | 66kV | 132kV |
Threshold Set within Range | 1.65kV To 4.4kV | 4.95kV To 13.2kV | 11kV To 13kV | 13.2kV To 59.4kV |
Response Time | <1 Sec | <1 Sec | <1 Sec | <1 Sec |
Auto-OFF | 3Min | 3Min | 3Min | 3Min |
Bridging Protection | YES | YES | YES | YES |
Spark Protection | YES | YES | YES | YES |
Battery Low | <7V | <7V | <7V | <7V |
Threshold | 3.02kV | 9.07kV | 12kV | 13.2kV |
Battery Current | <30mA | <30mA | <30mA | <30mA |
Green = Armed | YES | YES | YES | YES |
Red = V Detected | YES | YES | YES | YES |
Test / Arming Button | YES | YES | YES | YES |
PART# | 217HVD | 218HVD | 219HVD | 220HVD | 221HVD |
---|---|---|---|---|---|
System Voltage | 11/33kV | 44/132kV | 66/132kV | 6.6/132kV | 11/132kV |
Threshold Set within Range | 3.3kV To 4.95kV | 13.2kV To 19.8kV | 13.2kV To 29.7kV | 2kV To 3kV | 4.4kV To 6.6kV |
Response Time | <1 Sec | <1 Sec | <1 Sec | <1 Sec | <1 Sec |
Auto-OFF | 3Min | 3Min | 3Min | 3Mi | 3Min |
Bridging Protection | YES | YES | YES | YES | YES |
Spark Protection | YES | YES | YES | YES | YES |
Battery Low | <7V | <7V | <7V | <7V | <7V |
Threshold | 4.12kV | 13.2kV | 13.2kV | 2.5kV | 5kV |
Battery Current | <30mA | <30mA | <30mA | <30mA | <30mA |
Green = Armed | YES | YES | YES | YES | YES |
Red = V Detected | YES | YES | YES | YES | YES |
Test / Arming Button | YES | YES | YES | YES | YES |
PART# | 222HVD | 223HVD | 224HVD | 225HVD | 226HVD |
---|---|---|---|---|---|
System Voltage | 11/44kV | 33/132kV | 44kV | kV USER DEFINED | 12/36kV |
Threshold Set within Range | 4.4kV To 4.95kV | 13.2kV To 14.85kV | 6.6kV To 17.6kV | Xx kV To Xx Kv | 3.6kV To 5.4kV |
Response Time | <1 Sec | <1 Sec | <1 Sec | <1 Sec | <1 Sec |
Auto-OFF | 3Min | 3Min | 3Min | 3Mi | 3Min |
Bridging Protection | YES | YES | YES | YES | YES |
Spark Protection | YES | YES | YES | YES | YES |
Battery Low | <7V | <7V | <7V | <7V | <7V |
Threshold | 4.75kV | 13.2kV | 12kV | User's Spec | 5.4kV |
Battery Current | <30mA | <30mA | <30mA | <30mA | <30mA |
Green = Armed | YES | YES | YES | YES | YES |
Red = V Detected | YES | YES | YES | YES | YES |
Test / Arming Button | YES | YES | YES | YES | YES |
PART# | 227HVD | 228HVD | ---------- | ---------- | ---------- |
---|---|---|---|---|---|
System Voltage | 10/40kV | 9.2/33kV | ---------- | ---------- | ---------- |
Threshold Set within Range | 4.2kV To 4.4kV | 3.9kV To 4.1kV | ---------- | ---------- | ---------- |
Response Time | <1 Sec | <1 Sec | ---------- | ---------- | ---------- |
Auto-OFF | 3Min | 3Min | ---------- | ---------- | ---------- |
Bridging Protection | YES | YES | ---------- | ---------- | ---------- |
Spark Protection | YES | YES | ---------- | ---------- | ---------- |
Battery Low | <7V | <7V | ---------- | ---------- | ---------- |
Threshold | 4.3kV | 4kV | ---------- | ---------- | ---------- |
Battery Current | <30mA | <30mA | ---------- | ---------- | ---------- |
Green = Armed | YES | YES | ---------- | ---------- | ---------- |
Red = V Detected | YES | YES | ---------- | ---------- | ---------- |
Test / Arming Button | YES | YES | ---------- | ---------- | ---------- |