  FEATURES
● 4000 counts.
● Voltage measurement, current measurement, resistor 
   measurement, frequency counter, capacitor measurement.
● Bargraph indication.
● Range change function.
● Data hold function freezes the reading.
● REL function.
● Peak function.
● Diode measurement.
● Max / Min function.
● Continuity check.
● Low battery indication.
● Auto Power Off (APO) function.
● Safety design throughout with no exposed metal
   parts, shielded banana plugs and recessed input terminals.
  SPECIFICATIONS
   
 DC Voltage
  Ranges   Resolution   Accuracy 
  400mV   0.1mV   ±(1.0%rdg+3dgt)
  4V   1mV
 40V   10mV
 400V   100mV
  600V   1V
 Overload protection : 650V DC
 AC Voltage
  Ranges   Resolution   Accuracy 
  400mV   0.1mV  ±(0.5%rdg+3dgt)
  4V   1mV  ±(1.5%rdg+3dgt)
 40V   10mV
 400V   100mV
 600V   1V
 Overload protection : 650V AC rms
 Frequency Response : 0~400mV at 40Hz~120Hz
                                              4V~600V at 40Hz~500Hz
 AC Current
Ranges   Resolution   Accuracy 
400A  0.1A  ±(1.5%rdg+4dgt)
600A  1A  ±(2.0%rdg+4dgt)
 Frequency Response: 40Hz~500Hz
 DC Current
Ranges   Resolution   Accuracy 
400A  0.1A  ±(1.5%rdg+4dgt)
600A  1A  ±(2.0%rdg+4dgt)
 Resistance
  Ranges   Resolution   Accuracy 
 400 0.1 ±(1.5%rdg+3dgt)
4k 1
40k 10
400k 100
4M 1k
40M 10k ±(2.0%rdg+4dgt)
 Continuity
Ranges Audible threshold
400 Less than 35
 Frequency
  Ranges   Resolution   Accuracy 
 4kHz 1Hz ±(0.3%rdg+2dgt)
15kHz 10Hz
 Diode:
Ranges   Resolution   Accuracy 
2V 1mV ±(1.5%rdg+3dgt)
 Capacitor
  Ranges   Resolution   Accuracy 
4nF 1pF ±(2.5%rdg+4dgt)
40nF 10pF ±(2.0%rdg+4dgt)
400nF 100pF
4µF 1nF
40µF 10nF
400µF 100nF ±(2.5%rdg+4dgt)
4mF 1µF
40mF 10µF ±(3.0%rdg+4dgt)
 GENERAL
  Conductor size   35mm Max.
  Operating principle   Dual slope integration
  Over range indication   "O.L" indicated
  Low battery 
  indication
 
  Response time   Approx. 1 second
  Sample rate   Approx. 2 times per second
  Temperature &
  humidity for
  guaranteed
  0ºC to 50ºC
  80% Max.
  Storage temperature
  & humidity
  -10ºC to 60ºC
  80% Max.
  Battery life   Approx.100 hours on
  continuous use. (Alkaline)
  Dimensions   210(L) × 90(W) × 40(D)mm
  Weight
  (battery Included)
  Approx. 330g 
  Power source   One type 6F22
  (or equivalent), 9V manganese
  Safety standard   EN 61010-1 CAT III 600V
  EN 61326-1
     
   
 
   
     
   
   
     
   
     
   
   
   
     
   
     
   
   
   
   
   
   
   
   
   
   
   
     
   
   
   
guaranteed : 0oC to 50oC
    80% Max.
Storage temperature    
& humidity : -10oC to 60oC
    80% Max.
Battery life : Approx. 100 hours on
    continuous use.(Alkaline)
Dimensions : 210(L) × 90(W) × 40(D)mm
Weight    
(battery Included) : Approx. 330g
Power source : One type PP3, 6F22, 006P
    (or equivalent), 9V manganese.
Safety standard : EN 61010-1 CAT III 600V
    EN 61326-1
     
 


gotop