  FEATURES
● High quality Taut Band movement.
● Three insulation test voltages(DC) : 250V, 500V, 1000V.
● Two continuity test on "low ohms" : 3Ω & 500Ω.
● Compact and lightweight.
● AC voltmeter with linear scale up to 600 Vac.
● 200mA continuity short circuit current.
● 1mA test current on insulation test at nominal voltage.
● Automatic discharge of capacitive and inductive circuit with charge stored in the circuit under test.
● Live warning and display or external voltage presence.
● Fuse, air gap, crowbar and overload protected.
● On line battery monitoring shows if battery is ok.
● Manual zero ohm adjustment.
● Low battery consumption.
● Mirror scale.
● Push and turn locking switch for continuous and hand free testing.
● Designed for meet international standards.
● Supplied with high quality test leads.
● BS 16 edition.
 
  SPECIFICATIONS
Insulation  Resistance
 Test voltage (DC V)  250V     /    500V    /    1000V
 Output voltage on
 open circuit
 Rated test voltage +10%
 Measuring ranges  0-100MΩ / 0-200MΩ /  0-400MΩ
 Mid-scale value  1MΩ     /    2MΩ     /     4MΩ
 Scale multiplier  ×1/2     /      ×1       /       ×2
 Accuracy  ± 5% of indicated value
 Output short-
 circuit current
 1.0mA
Continuity
 Measuring ranges  3Ω / 500Ω
 Output short-
 circuit current
200 mA
 Accuracy  ± 1.5% of scale length
AC Voltage
 Range  0-600V AC
 Accuracy  ± 3% of scale length
General
 Voltage warning  Warning light circuit live lit From 90Vdc / 
 70Vac, Buzzer beep from 24V ac/dc
 Battery check  Battery check indicate good batteries from 8Vdc to
 13Vdc during a load test of 205mA.
 Battery OK : battery ok led lit from 6.5Vdc and is
 operative while testing.
 Dimensions  250(L) × 190(W) × 110(D)mm
 Weight
 (battery included)
 Approx. 1400g
 Power source  1.5V (AA) × 8  
 Safety standard  EN 61010-1 CAT III 600V
 EN 61326-1
 