 FEATURES
● Excellent shock resistance.
● Rugged nylon moulding.
● Auto on (when voltage detected).
● Excellent drop resistance.
● Good vibration resistance.
● Loud sound alarm indication.
● Built-in proving and self-test circuit.
● High bright color-coded LEDS.
● Works from standard 9V battery.
● Interchangeable contact electrode.
● Use in all whether conditions.
● Compatible with all link sticks.
● Lightweight, robust & compact.
● Models available from 11kV to 132kV.
● Suitable for indoor and outdoor use.
● Self(auto on) or manual arming.
● Easy access to batteries.
● Customized threshold on demand.
● Auto off (if no voltage detected).
● Waterproof design, protection class : IP65.
 SPECIFICATIONS

 

 PART#  213HVD  214HVD  215HVD  216HVD
 System Voltage  11kV  33kV  66kV  132kV
 Threshold
 Set within
 Range
 1.65kV
 To
 4.4kV
 4.95kV
 To
 13.2kV
 11kV
 To
 13kV
 11kV
 To
 13kV
 Response Time  <1 Sec  <1 Sec  <1 Sec  <1 Sec
 Auto-OFF  3Min  3Min  3Min  3Min
 Bridging
 Protection
 YES  YES  YES  YES
 Spark Protection  YES  YES  YES  YES
 Battery Low  <7V  <7V  <7V  <7V
 Threshold 3.02kV 9.07kV 12kV 12kV
 Battery Current  <30mA  <30mA  <30mA  <30mA
 Green = Armed  YES  YES  YES  YES
 Red = V Detected  YES  YES  YES  YES
 Test / Arming Button  YES  YES  YES  YES
 PART#  217HVD  218HVD  219HVD  220HVD  221HVD
 System Voltage  11/33kV 44/132kV 66/132kV 6.6/132kV 11/132kV
 Threshold
 Set within
 Range
3.3kV
To
4.95kV
11kV
To
13kV
11kV
To
13kV
2kV
To
3kV
4.4kV
To
6.6kV
 Response Time  <1 Sec  <1 Sec  <1 Sec  <1 Sec  <1 Sec
 Auto-OFF  3Min  3Min  3Min  3Min  3Min
 Bridging
 Protection
 YES  YES  YES  YES  YES
 Spark Protection  YES  YES  YES  YES  YES
 Battery Low  <7V  <7V  <7V  <7V  <7V
 Threshold 4.12kV 12kV 12kV 2.5kV 5kV
 Battery Current  <30mA  <30mA  <30mA  <30mA  <30mA
 Green = Armed  YES  YES  YES  YES  YES
 Red = V Detected  YES  YES  YES  YES  YES
 Test / Arming Button  YES  YES  YES  YES  YES
 PART#  222HVD  223HVD  224HVD  225HVD  226HVD
 System Voltage 11/44kV 33/132kV 44kV kV USER
DEFINED
12/36kV
 Threshold
 Set within
 Range
4.4kV
To
5kV
11kV
To
13kV
6.6kV
To
17.6kV
Xx kV
To
Xx Kv
5.0kV
To
6.0kV
 Response Time  <1 Sec  <1 Sec  <1 Sec  <1 Sec  <1 Sec
 Auto-OFF  3Min  3Min  3Min  3Min  3Min
 Bridging
 Protection
 YES  YES  YES  YES  YES
 Spark Protection  YES  YES  YES  YES  YES
 Battery Low  <7V  <7V  <7V  <7V  <7V
 Threshold 4.75kV 12kV 12kV User’sSpec 5.4kV
 Battery Current  <30mA  <30mA  <30mA  <30mA  <30mA
 Green = Armed  YES  YES  YES  YES  YES
 Red = V Detected  YES  YES  YES  YES  YES
 Test / Arming Button  YES  YES  YES  YES  YES

   
   
   
   
     
   
   
   
   
     
   
   
   
   
     

 

   
 


gotop